HP And IP Inner Casing Sealing Rings Replacement - 62.5 MW, Bhusawal.
Bhusawal : HP, IP Sealing rings, Impellers, CEP spares, Turbine internal of 210 MW
Balancing CW Pump Impellers
Balancing CW Pump Impellers
Balancing of PA Fan Impellers
Modification of PA Fan Impellers
CW Pump Impellers
CW Pump Impellers
Metal Spray Coating On BFP
Impeller Machining
Bhusawal: HP And IP Inner Casing Sealing Rings Replacement - 62.5 MW
• Sealing rings replacement of Siemens set (62.5 MW) unit was running on 42.5 MW load.
• OEM companies refused to carry out this work during capital overhaul.
• We developed special tooling to remove damaged sealing rings. Executed the work within stipulated period.
• From year 2000, the unit is running on 62.5 MW with same coal mill load.